{"product_id":"sroves-matavimo-reples-true-rms-ac-dc-10ma-1000a-yt-730933","title":"CLAMP MULTIM. TRUE RMS AC\/DC 10MA-1000A (YT-730933)","description":"YT-730933\u003cbr\u003eTRUE RMS AC\/DC CLAMP METER 10MA - 1000A\u003cbr\u003eBrand\u003cbr\u003eYato\u003cbr\u003eSymbol\u003cbr\u003eYT-730933\u003cbr\u003eAlternating voltage measurement\u003cbr\u003e0-750 V a.c.\u003cbr\u003eDirect voltage measurement\u003cbr\u003e0-1000 V d.c.\u003cbr\u003eAC\u003cbr\u003e0-1000 A\u003cbr\u003eDC\u003cbr\u003e0-1000 A\u003cbr\u003eResistance measurement\u003cbr\u003e0-60 M\u003cbr\u003eCapacitance measurement\u003cbr\u003e0-100 mF\u003cbr\u003eFrequency measurement\u003cbr\u003e0-10 MHz\u003cbr\u003eTemperature measurement\u003cbr\u003e-30 ~ +1000 C\u003cbr\u003eContinuity test\u003cbr\u003e0-50 \u003cbr\u003eConduction test\u003cbr\u003eyes\u003cbr\u003eDiode test\u003cbr\u003eYES\u003cbr\u003eBattery test\u003cbr\u003eyes\u003cbr\u003ePeak value recording\u003cbr\u003eyes\u003cbr\u003eNon-contact AC voltage detection NCV\u003cbr\u003eyes\u003cbr\u003eDimensions\u003cbr\u003e194x75x35 mm\u003cbr\u003eMaterial\u003cbr\u003eABS\u003cbr\u003eMax. clamp opening\u003cbr\u003e25 mm\u003cbr\u003eMax. wire diameter for measurement with clamp\u003cbr\u003e25 mm\u003cbr\u003eDisplay type\u003cbr\u003eLCD\u003cbr\u003eDisplay range\u003cbr\u003e6000\u003cbr\u003eLED backlight\u003cbr\u003eYES\u003cbr\u003eAudible signal\u003cbr\u003eyes\u003cbr\u003eAuto range measurement\u003cbr\u003eyes\u003cbr\u003eAutomatic power off\u003cbr\u003e15 min\u003cbr\u003eData Hold\u003cbr\u003eyes\u003cbr\u003eSampling rate\u003cbr\u003e3 times per second\u003cbr\u003eTRUE RMS\u003cbr\u003eyes\u003cbr\u003eFlashlight function\u003cbr\u003eYES\u003cbr\u003eBattery power supply\u003cbr\u003eBattery type\u003cbr\u003e3x1.5V; AAA\u003cbr\u003eLow battery indicator\u003cbr\u003eyes\u003cbr\u003eOperating temperature range\u003cbr\u003e0~40 C\u003cbr\u003eRelative working humidity Rh\u003cbr\u003e\u0026lt; 75 %\u003cbr\u003eStorage temperature\u003cbr\u003e-10 ~ +50 C\u003cbr\u003eWeight\u003cbr\u003e0.2 kg\u003cbr\u003eApplication\u003cbr\u003eelectrical\u003cbr\u003e\u003cbr\u003eUniversal clamp meter with TRUE RMS function, with automatic and manual range. It allows to perform basic and advanced measurements of electrical quantities. Using the measuring clamps, you can measure both direct and alternating current in the range from 10 mA to 1000 A. The measurement is performed without the need to disconnect the circuit or disconnect it from the power source. The meter allows you to measure significantly higher current than conventional electrical meters. The test probe leads have silicone, flexible and high-temperature resistant insulation.\u003cbr\u003e\u003cbr\u003eBasic measurements:\u003cbr\u003e\u003cbr\u003eAC voltage measurement: A.C. 0-750 V, TRUE RMS (40-1000 Hz)\u003cbr\u003eDC voltage measurement: D.C. 0-1000 V\u003cbr\u003eAC current measurement: A.C. 0-1000 A, TRUE RMS (40-1000 Hz)\u003cbr\u003eDC current measurement: D.C. 0-1000 A\u003cbr\u003eresistance measurement: 0-60 M\u003cbr\u003ediode test: IF 2 mA, UR 3.2 V\u003cbr\u003econtinuity test: 0-50 \u003cbr\u003eAdditional measurements:\u003cbr\u003e\u003cbr\u003ecapacitor capacitance measurement: 0-100 mF\u003cbr\u003efrequency measurement: 0-10 Mhz\u003cbr\u003etemperature measurement: -30 to 1000 C\u003cbr\u003enon-contact AC voltage detection: NCV\u003cbr\u003einrush current measurement\u003cbr\u003ephase presence measurement (probe function)\u003cbr\u003eMeasurement accuracy:\u003cbr\u003e\u003cbr\u003eExample of determining accuracy for AC current measurement. Calculations for measurement result: 30 A\u003cbr\u003e\u003cbr\u003emeasurement accuracy of the YT-730933 meter for this range is: (2.5%+10), resolution 0.01 A\u003cbr\u003emeasurement error calculation formula: (measurement result x 2%) + 30 x resolution\u003cbr\u003ecalculations: (30 x 2.5%) + 10 x 0.01 = 0.75 + 0.1 = 0.85 A\u003cbr\u003eActual result taking into account the measurement error for the 30 A indication = 30 0.85 A.\u003cbr\u003e\u003cbr\u003eresult taking into account the measurement error for the AC voltage measurement indication: 235 V = 235 2.85 V\u003cbr\u003eresult taking into account the measurement error for the DC voltage measurement indication: 12 V = 12 0.146 V\u003cbr\u003eThe table with the resolution and accuracy for a given measurement can be found in the user manual.\u003cbr\u003e\u003cbr\u003eBuilt-in functions:\u003cbr\u003e\u003cbr\u003eTRUE RMS - a meter with this function displays the true effective value of the alternating voltage or current. Unlike averaging meters, devices with TRUE RMS display the correct value not only for a sinusoidal waveform, but also for distorted sinusoidal waveforms, e.g. higher harmonics, or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.\u003cbr\u003eNCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in an insulated wire, it can also indicate the phase wire.\u003cbr\u003eLINE - contact detection of alternating voltage, works like a traditional tester. After inserting the measuring probe into the hole in the socket, in the case of the presence of a phase, four lines will appear on the display, the signal diode will light up and an intermittent sound signal will be emitted.\u003cbr\u003eAUTO - automatic adjustment of the measurement range. When measuring unknown values using a meter with manual range adjustment using the knob, measurements should be taken successively from the largest range to the most accurate. Otherwise, we risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to take one measurement and the meter will automatically find the optimal range. The meter starts in AUTO mode by default.\u003cbr\u003eRAN - manual change of the measurement range\u003cbr\u003eDATA HOLD - saving the currently measured value on the display\u003cbr\u003eINR - measurement of the starting current using measuring clamps. The meter will measure the starting current 80 ms after starting the device.\u003cbr\u003eAdditional information:LCD display, maximum displayed result: 6000\u003cbr\u003ebacklighting of the screen and the clamp measuring field\u003cbr\u003esound signal in the continuity test for resistance below 50\u003cbr\u003eclamps open to 25 mm\u003cbr\u003emeasuring probes 14 cm long\u003cbr\u003elength of the cable with probes: 103 cm\u003cbr\u003ediameter of the cable with insulation: 3.6 mm\u003cbr\u003ecover included\u003cbr\u003edesign with overload protection\u003cbr\u003eautomatic shutdown of the meter after 15 minutes of inactivity\u003cbr\u003epossibility of turning off the automatic shutdown mode of the device\u003cbr\u003elow battery indicator\u003cbr\u003epower supply: three 1.5 V (AAA) batteries\u003cbr\u003eNote!\u003cbr\u003e\u003cbr\u003eCurrent intensity measurement using clamp meters is performed only and exclusively on a single core, a single wire. Fastening the clamps to a multi-core cable without isolating a single core will show an incorrect result or zero current flow","brand":"Yato","offers":[{"title":"Default Title","offer_id":56528450126206,"sku":"YT-730933","price":45.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0965\/5097\/7918\/files\/1ca38ca7a9f13e46a3b0405821311f4d.jpg?v=1767519089","url":"https:\/\/irankiuturgus.com\/en-fi\/products\/sroves-matavimo-reples-true-rms-ac-dc-10ma-1000a-yt-730933","provider":"irankiuturgus.com","version":"1.0","type":"link"}