{"product_id":"sroves-matavimo-reples-true-rms-ac-dc-10ma-600a-yt-730934","title":"Srovės matavimo replės | TRUE RMS AC\/DC 10MA - 600A (YT-730934)","description":"YT-730934\u003cbr\u003eTRUE RMS AC\/DC CLAMP METER 10MA - 600A\u003cbr\u003eBrand\u003cbr\u003eYato\u003cbr\u003eEntity responsible for this product in the EU\u003cbr\u003eTOYA S.A.More\u003cbr\u003eMeasurement of alternating voltage\u003cbr\u003e0-600 V a.c.\u003cbr\u003e\u003cbr\u003eMeasurement of direct voltage\u003cbr\u003e0-600 V d.c.\u003cbr\u003eAC Current\u003cbr\u003e0-600 A\u003cbr\u003eDC Current\u003cbr\u003e0-600 A\u003cbr\u003eResistance Measurement\u003cbr\u003e0-60 M\u003cbr\u003eCapacitance Measurement\u003cbr\u003e0-60 mF\u003cbr\u003eFrequency Measurement\u003cbr\u003e0-300 kHz\u003cbr\u003eTemperature Measurement\u003cbr\u003e-30 ~ +1000  C\u003cbr\u003eContinuity Test\u003cbr\u003e0-50 \u003cbr\u003eConduction Test\u003cbr\u003eyes\u003cbr\u003eDiode Test\u003cbr\u003eyes\u003cbr\u003eBattery Test\u003cbr\u003eyes\u003cbr\u003ePeak Value Recording\u003cbr\u003eyes\u003cbr\u003eTRUE RMS\u003cbr\u003eyes\u003cbr\u003eData Hold\u003cbr\u003eyes\u003cbr\u003eNCV Non-Contact Detection of AC Voltage\u003cbr\u003eyes\u003cbr\u003eDimensions\u003cbr\u003e185x65x30 mm\u003cbr\u003eMaterial\u003cbr\u003eABS\u003cbr\u003eMax. Clamp Opening\u003cbr\u003e25 mm\u003cbr\u003eMax. Wire Diameter for Measurement with Clamp\u003cbr\u003e25 mm\u003cbr\u003eDisplay Type\u003cbr\u003eLCD\u003cbr\u003eLED Backlight\u003cbr\u003eyes\u003cbr\u003eDisplay Range\u003cbr\u003e6000\u003cbr\u003eSignal sound\u003cbr\u003eyes\u003cbr\u003eAutomatic measurement range\u003cbr\u003eyes\u003cbr\u003eSampling rate\u003cbr\u003e3 times per second\u003cbr\u003eAutomatic power off\u003cbr\u003e15 min\u003cbr\u003eFlashlight function\u003cbr\u003eyes\u003cbr\u003eLow battery indicator\u003cbr\u003eyes\u003cbr\u003ePower supply\u003cbr\u003ebattery\u003cbr\u003eBattery type\u003cbr\u003e3x1.5V; AAA\u003cbr\u003eOperating temperature range\u003cbr\u003e0~40  C\u003cbr\u003eRelative working humidity Rh\u003cbr\u003e\u0026lt;75 %\u003cbr\u003eStorage temperature\u003cbr\u003e-10 ~ +50  C\u003cbr\u003eWeight\u003cbr\u003e0.165 kg\u003cbr\u003eApplication\u003cbr\u003eelectrical\u003cbr\u003eSymbol\u003cbr\u003eYT-730934\u003cbr\u003e\u003cbr\u003eUniversal clamp meter with automatic range for each measurement allows for performing basic and advanced measurements of electrical quantities. The meter is equipped with measuring clamps that allow for measuring the intensity of direct current and alternating current in a single wire using the built-in HALL sensor. The measurement is performed without the need to disconnect the circuit or disconnect it from the power source and allows for measuring a much higher current intensity than in the case of conventional electrical meters. The measuring probe leads have silicone, flexible and resistant to high temperatures insulation.\u003cbr\u003e\u003cbr\u003eNote: Meters capable of measuring DC current intensity, including the YT-730934, use a Hall sensor that measures the value of the magnetic field intensity. The magnetic field on Earth occurs naturally, as a result of which the readings of the DC current meter are non-zero. Each time, before measuring the DC current intensity, bring the meter close to the tested wire, zero it with the REL button, then attach it to the tested wire and read the result.\u003cbr\u003e\u003cbr\u003eBasic measurements:\u003cbr\u003e\u003cbr\u003eAC voltage: 0-600 V, TRUE RMS (40-1000 Hz)\u003cbr\u003eDC voltage: 0-600 V\u003cbr\u003eAC current intensity: A.C. 0-600 A, TRUE RMS (40-1000 Hz)\u003cbr\u003eDC Current: D.C. 0-600 A\u003cbr\u003eResistance: 0-60 M\u003cbr\u003eDiode Test: IF 1.5 mA, UR 3 V\u003cbr\u003eContinuity Test: 0-50 \u003cbr\u003eAdditional Measurements:\u003cbr\u003e\u003cbr\u003eAC and DC Voltages in Low Impedance Mode: 0-600 V\u003cbr\u003eCapacitor Capacitance: 0-60 mF\u003cbr\u003eFrequency: 0-300 kHz\u003cbr\u003eTemperature: -30 to 1000C\u003cbr\u003eNon-Contact AC Voltage Detection: NCV\u003cbr\u003eAccuracies:\u003cbr\u003e\u003cbr\u003eExample of determining accuracy for AC current measurement. Calculations for measurement result: 30 A\u003cbr\u003e\u003cbr\u003emeasurement accuracy of the YT-730934 meter for this range is: (2.0%+30), resolution 0.01 A\u003cbr\u003emeasurement error calculation formula: (measurement result x 2%) + 30 x resolution\u003cbr\u003ecalculations: (30 x 2%) + 30 x 0.01 = 0.6 + 0.3 = 0.90 A\u003cbr\u003eActual result taking into account the measurement error for the 30 A indication = 30  0.90 A\u003cbr\u003e\u003cbr\u003eresult taking into account the measurement error for the AC voltage measurement indication: 235 V = 235  2.65 V\u003cbr\u003eresult taking into account the measurement error for the DC voltage measurement indication: 12 V = 12  0.09 V\u003cbr\u003eThe table with the resolution and accuracy for a given measurement can be found in the user manual.\u003cbr\u003e\u003cbr\u003eBuilt-in functions:\u003cbr\u003e\u003cbr\u003eTRUE RMS - the meter displays the true effective value of the AC voltage\/current. Unlike averaging meters, devices with TRUE RMS display the correct value not only for a sinusoidal waveform, but also for distorted sinusoidal waveforms, e.g. with higher harmonics or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.\u003cbr\u003eVlowZ - measurement of AC and DC voltage in low impedance mode. The phenomenon commonly called ghost voltage can make it difficult to diagnose the power supply network, e.g. in industrial buildings. It consists in the appearance of voltage on an unconnected wire in which voltage has been induced from a wire connected to the network through the same channel. The LowZ function lowers the impedance of the meter's measuring sockets 10 times compared to the standard measurement mode, then the meter samples the voltage and draws a slightly higher current and thus discharges the charge accumulated in the wire. As a result, we get a voltage measurement without the so-called ghost voltage\u003cbr\u003eNCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in an insulated wire and can also indicate the phase wire\u003cbr\u003eAUTO - automatic adjustment of the measurement range (one measurement is enough), activated by default. When measuring unknown values using a meter with manual range change using the knob, measurements should be taken successively from the largest range to the range giving the most accurate result - otherwise we risk damaging the device.\u003cbr\u003e\u003cbr\u003eDATA HOLD - saving the currently measured value on the display\u003cbr\u003ePEAK HOLD - saving the highest measured value on the display using measurement probes\u003cbr\u003eINRUSH current - measurement of the inrush current using measuring clamps. The meter will measure the current intensity within 100 ms of starting the device\u003cbr\u003eREL - relative value function. Allows to zero the meter readings. Necessary in the DC current measurement mode. The Hall sensor measures the value of the ambient electromagnetic field and shows the result on the display. Before measuring the DC current intensity, bring the meter close to the tested wire, zero it, then place the clamps on the tested wire. Thanks to this, we will obtain a result that is not disturbed by the values of the ambient electromagnetic field indications\u003cbr\u003eAdditional information:\u003cbr\u003e\u003cbr\u003eLCD display, maximum displayed result: 6000\u003cbr\u003ebacklighting of the screen and the clamp measuring field\u003cbr\u003esound signal in the circuit continuity test for resistance below 50 \u003cbr\u003epossibility of switching on diode and circuit continuity tests separately\u003cbr\u003ethe clamps open to 25 mm and allow for the measurement of a single wire with a maximum diameter of 25 mm\u003cbr\u003emeasuring probes 14.5 cm long\u003cbr\u003elength of the cable with probes: 97 cm\u003cbr\u003ediameter of the cable with insulation: 3.5 mm\u003cbr\u003ethe set includes a cover\u003cbr\u003edesign with overload protection\u003cbr\u003eautomatic shutdown of the meter after 15 minutes of inactivity (this function can be switched off)\u003cbr\u003elow battery indicator\u003cbr\u003epower supply: 2 x 1.5 V (AAA) batteries\u003cbr\u003eAttention!\u003cbr\u003e\u003cbr\u003eCurrent measurement using clamp meters is performed only and exclusively on a single strand, a single wire. Attaching clamps to a multi-strand cable without isolating a single strand will show an incorrect result or zero current flow.\u003cbr\u003e","brand":"Yato","offers":[{"title":"Default Title","offer_id":56528450224510,"sku":"YT-730934","price":38.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0965\/5097\/7918\/files\/961e33e9a51e474a9738673a6c1afdc6.jpg?v=1767519107","url":"https:\/\/irankiuturgus.com\/products\/sroves-matavimo-reples-true-rms-ac-dc-10ma-600a-yt-730934","provider":"irankiuturgus.com","version":"1.0","type":"link"}