Skaitmeninis lazerinis termometras / pirometras | LCD ekranas | -50C+600C (YT-73200)
Skaitmeninis lazerinis termometras / pirometras | LCD ekranas | -50C+600C (YT-73200)
Kodas: YT-73200Kaina 1599 € su PVM1649 €Sutaupykite 050 €Netinka kaina? Siūlyk savo!Šią prekę turime sandėlyje.Dėl prekės pristatymo termino maloniai prašome kreiptis elektroniniu paštu
Pirkdami galite gauti 1599 taškus.Lizingo skaičiuoklės- sbl
- esto3
Skaitmeninis lazerinis termometras / pirometras | LCD ekranas | -50C+600C (YT-73200)
prekės ženklas-
Product description
YT-73200 non-contact infrared thermometer with a large color LCD display, an extensive circle-shaped laser sight, emissivity adjustment and numerous functions facilitating work, among others max / min, high and low temperature alarm and calibration function. It will find its application in many industries, incl. in construction, automotive, gastronomy, in the food industry and in the household.TEMPERATURE MEASUREMENT
temperature measurement range: -50 ° C ~ + 600 ° C (-58F ~ + 1112F)
measurement accuracy: + -2 ° C / 2%
measurement resolution: 0.1 ° C / ° F - temperature display with one digit after the decimal point, e.g. 236.6 ° C
OTHER DATAoptical resolution: 1:12 - at a distance of 12 cm from the device, the surface temperature will be measured from a circle-shaped field with a diameter of 1 cm
emissivity: regulation in the range 0.10-1.00 - factory setting 0.95
spectral response: 5-14 μm
measurement speed: 0.5 s
working in ambient temperature: 0 ° C-40 ° C (14 ° F - 140 ° F)
FUNCTIONSdisplaying the maximum and minimum temperature from a given measurement [MAX], [MIN]
display of the ambient temperature [AT]
high and low temperature alarm [Hi], [Low] - sound signal, displaying HI and LO respectively
alarm for operation in too low or too high ambient temperature - displaying AH and AL, respectively
emissivity regulation [EMS]
device calibration [CAL] - possibility of making the sensor indications more precise in the range from -5.0 to + 5 ° C
low battery display at voltage below 2.5V [battery symbol]
automatic shutdown of the device after 7 seconds of inactivity
ADDITIONAL INFORMATIONhousing material: ABS
power supply: 2 x 1.5V AAA
dimensions: 90 * 39 * 150 mm
weight (including batteries): 155 g
DEFINITIONSIR radiation - each object, depending on its current temperature, emits adequate infrared radiation. An IR thermometer uses optics to focus this radiation on an infrared sensor, which first converts it into heat, and then into electricity. The energy value is then read and converted into a temperature indication. The entire process in YATO pyrometers takes no more than 0.5 seconds.
Emissivity - this is a parameter that determines the ability of an object to emit thermal radiation. Most organic, varnished and oxidized materials have an emissivity of 0.95 and this is the parameter that is preset at the factory. However, some materials, such as lead or aluminum, have much lower emissivity, so if there is a need to obtain a measurement that is as close to the real one as possible, you should first set the emissivity parameter to the value appropriate for a given material. Emissivity tables should be found in the scientific literature or on the Internet.
Low and high temperature alarm - this function is useful, for example, in locating thermal bridges on cold days. Measure the temperature in the center of the wall to get a benchmark, then set the low temperature alarm a few degrees lower depending on the outside temperature. The next step is to measure the temperature in places where thermal bridges occur most often, eg wall-to-ceiling joints, around window frames, etc. If the temperature reading drops below the set value in the alarm, then you will hear an acoustic signal and an additional indication on the display.
Measurement accuracy - optics and control electronics in YATO pyrometers ensure high accuracy and repeatability of measurements. However, due to many manufacturer-independent variables, including humidity and ambient temperature in the measurement places, it is impossible to calibrate the device so that its accuracy is 100% in all conditions. The manufacturer declares the possibility of a measurement error of 2%, but not less than + -2 ° C at an ambient temperature of 0 ° C-40 ° C. This means that when setting the correct emissivity, the measurement result of 100 ° C should be interpreted as a value in the range of 102-98 ° C.
Parameters
Temperature measurement: -50 to 600 ° C-------- Prekių nuotraukos skirtos tik iliustraciniams tikslams ir yra pavyzdinės. Prekės aprašyme esančios video nuorodos yra tik informacinio pobūdžio, todėl jose pateikiama informacija gali skirtis nuo pačios prekės. Originalių produktų spalvos, užrašai, parametrai, matmenys, dydžiai, funkcijos, ir (ar) bet kurios kitos savybės dėl savo vizualinių ypatybių gali atrodyti kitaip negu realybėje, todėl prašome vadovautis prekių charakteristikomis, kurios nurodytos aprašymuose. Kilus klausimams, maloniai prašome skambinti telefonu +370 635 76667 arba rašyti info@irankiuturgus.com