ROOF HEATING TORCH WITH BURNERS | 1500~1800°C (73340)
Before 12:00 noon – dispatch the same business day*
Lithuanian time. COD: from receipt of the order; advance payment: from receipt of payment. Later orders and non-working days: next business day. Palletised / oversized goods may need 1 additional business day.
Within Lithuania, carrier transit after dispatch usually takes 1 business day.
Delivery from 2,99 €
- 30-day return guarantee
- Self-service collection in Vilnius, 24/7 after the ready notification
Delivery
Delivery
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
Typical carrier transit time after dispatch: Lithuania – 1 business day; Latvia – 1 business day; Estonia – 1–2 business days; Finland – 3–5 business days. We deliver only to countries offered at checkout. Carrier delays can extend these estimates.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Pickup
Pickup
Collection in Vilnius
Collection in Vilnius: B. Sruogos g. 52. Enter through the wooden gate between numbers 52 and 54; identify your parcel by its order number. Self-service collection is available 24/7, but please come only after receiving confirmation that your order is ready. Collection is available around the clock; orders are prepared on business days.
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Manufacturer:
Vorel
Description
Description
TECHNICAL PARAMETERS:
Number of burner cups - 3
Cup size [mm] - 25; 35; 40
Nominal gas supply pressure [MPa] - 1.2
Flame temperature [oC] - 1500-1800
Nominal flow [g / h] - 2000
Thermal load [kW] - 19.5
Hose length [m] - 2
Torch length (without hose length) [mm] - 360
Purpose / Use
Gas burners are designed for heating, drying and roofing work. Thanks to the power supply using a bottle with compressed butane (it is also possible to supply a mixture of propane and butane gas) it is possible to work in places without energy sources.
Usage
The device should be installed in accordance with the operating instructions. Tighten the hose to the assembled device. Connect the other end of the hose to the gas bottle.
Check tightness of connections by slightly unscrewing the cylinder valve, then apply soapy water to the connections. In case of gas bubbles, turn off the gas supply and tighten the leaky connections. Repeat the procedure until complete gas tightness is ensured.
Unscrew the gas valve in the cylinder and then unscrew the valve of the device, but only enough to allow gas to escape. Ignite the gas at the outlet of the cup. To do this, use a special lighter designed to ignite portable gas burners. After about 20 seconds, press the lever of the burner. If the flame is too short, set the gas pressure using the burner valve. After releasing the lever, the flame returns to the saving mode.
After finishing work, close the cylinder valve and then, after the flame is extinguished, set aside the burner on a non-flammable surface to cool down. After cooling, proceed with maintenance.
Details of assembly, operation and maintenance of the device are in the enclosed operating instructions.
Contents of the package
Burner (G3 / 8 "-19)
2 m hose (G3 / 8 "-19, 21.8-14)
Burners 25mm, 35mm, 50mm
Technical data
Index number 73340
EAN 5906083733406
Brand Vorel
Gross weight (kg) 1.3500
Pal 210
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
