BATTERY TESTER 6/12V (YT-83111)
Before 12:00 noon – dispatch the same business day*
Lithuanian time. COD: from receipt of the order; advance payment: from receipt of payment. Later orders and non-working days: next business day. Palletised / oversized goods may need 1 additional business day.
Within Lithuania, carrier transit after dispatch usually takes 1 business day.
Delivery from 2,99 €
- 30-day return guarantee
- Self-service collection in Vilnius, 24/7 after the ready notification
Delivery
Delivery
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
Typical carrier transit time after dispatch: Lithuania – 1 business day; Latvia – 1 business day; Estonia – 1–2 business days; Finland – 3–5 business days. We deliver only to countries offered at checkout. Carrier delays can extend these estimates.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Pickup
Pickup
Collection in Vilnius
Collection in Vilnius: B. Sruogos g. 52. Enter through the wooden gate between numbers 52 and 54; identify your parcel by its order number. Self-service collection is available 24/7, but please come only after receiving confirmation that your order is ready. Collection is available around the clock; orders are prepared on business days.
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Manufacturer:
Yato
Description
Description
Yato
Entity responsible for this product in the EU
TOYA S.A.More
Series
GRE
Operating voltage
6, 12 V d.c.
Voltage range
0-16 V d.c.
CCA range
200-1000 A
Load measurement current
135 A
Load test time mode
10 s / 5 min
Tested accumulators type
lead-acid
Voltage indicator type
analog
Working temperature range
0~40 C
Storage temperature
0~55 C
Weight
1.1 kg
Application
checking the battery charge and wear status
Symbol
YT-83111
Analog battery tester designed for quick and reliable diagnosis of the state of charge and level of battery exploitation. Allows for evaluation of their actual performance through a test under real load, especially useful in workshops and technical services.
It supports 6 V and 12 V DC installations, enabling control of lead-acid batteries with a capacity of 30-135 Ah, as well as 12-volt lithium batteries. The applied analog voltage indicator ensures an immediate reading without delays.
Features and functions:
enables diagnostics of 6 V and 12 V lead-acid batteries with a capacity of 30-135 Ah and 12 V lithium batteries
load current at 135 A ensures a reliable test of cell condition
the applied temperature compensation mechanism corrects voltage by 0.1 V for each 10C relative to the base temperature of 70C, increasing measurement reliability in variable working conditions
test under real load allows for evaluating the battery's ability to deliver starting current
the device offers two time modes for load testing:
10 seconds - quick diagnosis of current state
5 minutes - in-depth test, useful for evaluating used or problematic batteries
the stainless steel metal housing increases mechanical resistance and device durability
high-temperature resistant microporous plate insulation improves safety during load tests
ventilation hole in the lower part of the housing effectively dissipates heat
measurement cables with an effective length of 330 mm and a cross-section of 8 mm2 limit voltage drops and stabilize measurements
CCA measurement range from 200 to 1000 A allows evaluation of both standard and high-power sources
Technical data:
operating voltage: 6 / 12 V DC
voltage range: 0-16 V DC
CCA measurement range: 200-1000 A
load measurement current: 135 A
load test time mode: 10 s / 5 min
type of tested batteries: lead-acid
voltage indicator: analog
operating temperature: 0-40 C
storage temperature: 0-55 C
weight: 1.1 kg
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.