DIGITAL MULTIMETER TRUE RMS LCD 25000 (YT-730895)
Before 12:00 noon – dispatch the same business day*
Lithuanian time. COD: from receipt of the order; advance payment: from receipt of payment. Later orders and non-working days: next business day. Palletised / oversized goods may need 1 additional business day.
- 30-day return guarantee
- Self-service collection in Vilnius, 24/7 after the ready notification
Delivery
Delivery
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
Typical carrier transit time after dispatch: Lithuania – 1 business day; Latvia – 1 business day; Estonia – 1–2 business days; Finland – 3–5 business days. We deliver only to countries offered at checkout. Carrier delays can extend these estimates.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Pickup
Pickup
Collection in Vilnius
Collection in Vilnius: B. Sruogos g. 52. Enter through the wooden gate between numbers 52 and 54; identify your parcel by its order number. Self-service collection is available 24/7, but please come only after receiving confirmation that your order is ready. Collection is available around the clock; orders are prepared on business days.
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Manufacturer:
Yato
Description
Description
TRUE RMS AC+DC LCD 25000 DIGITAL METER
Brand
Yato
Entity responsible for this product in the EU
TOYA S.A.More
Measurement of alternating voltage
0-750 V a.c.
Measurement of direct voltage
0-1000 V d.c.
AC Current
0-20 A
DC Current
0-20 A
Resistance Measurement
0-250 M
Capacitance Measurement
0-99.99 mF
Frequency Measurement
0-10 MHz
Temperature Measurement
-20 ~ +1000 C
Duty Cycle Measurement
1 99 %
Continuity Test
0-50 M
Conduction Test
yes
Diode Test
yes
Minimum Measurement Value
yes
Maximum Measurement Value
yes
Relative Value
yes
TRUE RMS
yes
Data Hold
yes
NCV Non-Contact Detection of AC Voltage
yes
Dimensions
180x90x50 mm
Material
ABS
Display Type
LCD
LED Backlight
yes
Display Range
25000
Signal sound
yes
Automatic measurement range
yes
Sampling rate
3 times per second
Bargraph
0-100
Automatic power off
15 min
Flashlight function
no
Low battery indicator
yes
Battery power supply
Battery type
2x1.5V; AA
Operating temperature range
0~40 C
Relative working humidity Rh
<75 %
Storage temperature
-10 ~ +50 C
Weight
0.26 kg
Application
electrical
Symbol
YT-730895
A universal meter with TRUE RMS function and automatic range for each measurement. Counts up to 25,000 digits. Allows to perform basic and advanced measurements of electrical quantities.
Large multifunction LCD display, a number of functions facilitating measurements, wide measurement ranges, speed of operation and industrial precision will be appreciated by electronics engineers, electricians and home DIY enthusiasts. Solid housing equipped with a red PVC holster with an anti-slip structure, with dedicated places for measurement probes. The holster reduces the risk of the meter slipping out of your hands and reduces the effects of a fall. The measurement probe leads have silicone, flexible and high-temperature resistant insulation.
Basic measurements:
AC voltage: 0-750 V, TRUE RMS (40-1000 Hz)
DC voltage: D.C. 0-1000 V
AC current intensity: A.C. 0-20 A, TRUE RMS (40-1000 Hz)
DC current intensity: D.C. 0-20 A
resistance: 0-250 M
diode test: IF 1.8 mA, UR 3.2 V
continuity test: 0-50
Additional measurements:
AC+DC voltage: 1-1000 V
capacitor capacitance: 0-99.99 mF
frequencies: 0-10 Mhz
fill factor: 1-99%
temperatures: -20 to 1000C
non-contact AC voltage detection: NCV
Measurement accuracy:
Example of determining accuracy for AC voltage measurement. Calculations for the measurement result: 235 V
the measurement accuracy of the YT-730895 metre for this range is: (0.3% + 3), resolution 0.1 V
calculations of the measurement error formula: (measurement result x 0.3%) + 3 x resolution
calculations: (235 x 0.3%) + 3 x 0.1 = 0.705 + 0.3 = 1.005 V
Actual result taking into account the measurement error for the 235 V indication = 235 1.005 V
result taking into account the measurement error for the DC voltage measurement indication: 12 V = 12 0.009 V
result taking into account the measurement error for the AC current measurement indication: 8 A = 8 0.067 A
The table with the resolution and accuracy for a given measurement can be found in the user manual.
Functions:
TRUE RMS - the meter displays the true effective value of the alternating voltage/current. Unlike averaging meters, devices with TRUE RMS display the correct value not only for a sinusoidal waveform, but also for distorted sinusoidal waveforms, e.g. higher harmonics or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.
NCV - non-contact detection of alternating voltage by inductive method. The meter detects the presence of voltage in an insulated wire using the NCV sensor on the front of the device
AUTO - automatic adjustment of the measurement range (one measurement is enough), activated by default. In the case of measuring unknown values using a meter with manual range change using the knob, measurements should be performed successively from the largest range to the range giving the most accurate result - otherwise we risk damaging the device.
RANGE - manual change of measurement range, useful when checking many identical components with known values, e.g. a series of resistors. Manual setting of the range will significantly shorten the time of such measurements
REL - using the function during measurement will zero the display and accept the value visible before the display as the reference level. The next measurement will show the difference between the measured value and the stored reference value
SEL - change of measurement mode, e.g. from AC to DC voltage measurement
MAX/MIN - save the maximum or minimum value from the current measurement on the display
HOLD - save the currently measured value on the display
Additional information:
LCD display, maximum displayed result: 25000
backlight
sound and light signal in the continuity test for resistance below 50
possibility to enable diode and continuity tests separately
14.5 cm long measuring probes
length of the cable with probes: 97 cm
diameter of the cable with insulation: 3.5 mm
immersion probe for temperature measurement
point probe for temperature measurement
design with overload protection
ABS housing
automatic shutdown of the meter after 15 minutes of inactivity (this function can be turned off)
low battery indicator
warning light at the sockets for measuring current
needle tips for measuring small SMD components
soft case with zipper
power supply: 3 x 1.5 V (AA) batteries
Payment methods