CLAMP MULTIMETER TRUE RMS AC 600A (YT-730935)
Before 12:00 noon – dispatch the same business day*
Lithuanian time. COD: from receipt of the order; advance payment: from receipt of payment. Later orders and non-working days: next business day. Palletised / oversized goods may need 1 additional business day.
- 30-day return guarantee
- Self-service collection in Vilnius, 24/7 after the ready notification
Delivery
Delivery
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
Typical carrier transit time after dispatch: Lithuania – 1 business day; Latvia – 1 business day; Estonia – 1–2 business days; Finland – 3–5 business days. We deliver only to countries offered at checkout. Carrier delays can extend these estimates.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Pickup
Pickup
Collection in Vilnius
Collection in Vilnius: B. Sruogos g. 52. Enter through the wooden gate between numbers 52 and 54; identify your parcel by its order number. Self-service collection is available 24/7, but please come only after receiving confirmation that your order is ready. Collection is available around the clock; orders are prepared on business days.
We prepare orders every business day
Orders received and paid for before 12:00 noon Lithuanian time on a business day are dispatched or prepared for collection that business day. Orders received or paid for at or after 12:00 are prepared and dispatched on the next business day.
For cash on delivery (COD), the cut-off is based on when we receive the order. For bank transfers and other advance payments, it is based on when we receive payment for the submitted order.
Orders received or paid for at weekends, on Lithuanian public holidays or other statutory non-working days are prepared on the next business day. We announce any additional closures or holidays on our website.
Palletised and oversized goods may require one additional business day. Special-order products follow the lead time stated on the product page; the usual 0–1-business-day preparation time does not apply to them.
Carrier transit time starts at dispatch, not at order placement. Carrier working days and public holidays in the destination country may affect the delivery date.
Preparation examples
- A regular-stock order received and paid for before 12:00 on Monday is prepared on Monday; at or after 12:00 – on Tuesday.
- A regular-stock order received and paid for before 12:00 on Friday is prepared on Friday; at or after 12:00 or over the weekend – on Monday, provided it is a business day.
- If the expected preparation day is a public holiday or another non-working day, preparation moves to the next business day. Palletised and oversized orders may take one further business day.
- For COD orders, only receipt of the order before the cut-off is required in these examples.
For questions or an urgent order, contact: info@irankiuturgus.com, +370 635 76667.
Manufacturer:
Yato
Description
Description
TRUE RMS AC CLAMP METER 600A
Brand
Yato
Entity responsible for this product in the EU
TOYA S.A.More
Measurement of alternating voltage
0-600 V a.c.
Measurement of direct voltage
0-600 V d.c.
Alternating Current
0-600 A
Resistance Measurement
0-40 M
Continuity Test
0-50
Conduction Test
yes
Diode Test
yes
Battery Test
yes
TRUE RMS
yes
Data Hold
yes
Non-contact AC Voltage Detection NCV
yes
Dimensions
185x71x35 mm
Material
ABS
Max. Clamp Opening
26 mm
Max. Wire Diameter for Measurement with Clamps
26 mm
Display Type
LCD
LED Backlight
yes
Display Range
3999
Audible Signal
yes
Automatic Measuring Range
yes
Sampling Rate
3 times per second
Automatic Power Off
20 min
Flashlight Function
yes
Low Battery Indicator
yes
Power Supply
Battery
Type battery
3x1.5V; AAA
Operating temperature range
0~40 C
Relative working humidity Rh
<75 %
Storage temperature
-10 ~ +50 C
Weight
0.15 kg
Application
electrical
Symbol
YT-730935
Universal clamp meter with automatic range. Allows to perform basic and advanced electrical measurements. Equipped with measuring clamps, which allow to measure the intensity of alternating current in a single wire using the inductive method. The measurement is performed without the need to disconnect the circuit or disconnect it from the power source and allows to measure much higher current intensity than in the case of conventional electrical meters.
Basic measurements:
measurement of alternating voltage: A.C. 0-600 V, TRUE RMS (40-1000 Hz)
measurement of direct voltage: D.C. 0-600 V
AC current measurement: A.C. 0.001-600 A, TRUE RMS (40-1000 Hz)
Resistance measurement: 0.1 - 40 M
Diode test: IF: 1 mA, UR: 2.3 V
Continuity test: 0-50
Additional measurements:
Non-contact AC voltage detection: NCV
Phase presence measurement (probe function)
Measurement accuracy:
Example of determining accuracy for AC current measurement. Calculations for measurement result: 30 A
measurement accuracy of the YT-730935 metre for this range is: (2.5%+5), resolution 0.01 A
measurement error calculation formula: (measurement result x 2.5%) + 5 x resolution
calculations: (30 x 2.5%) + 5 x 0.01 = 0.75 + 0.05 = 0.80 A
Actual result taking into account the measurement error for the 30 A indication = 30 0.80 A.
result taking into account the measurement error for the AC voltage measurement indication: 235 V = 235 3.12 V
result taking into account the measurement error for the DC voltage measurement indication: 12 V = 12 0.126 V
The table with the resolution and accuracy for a given measurement can be found in the user manual.
Built-in functions:
TRUE RMS - a meter with this function displays the true effective value of the alternating voltage/current. Unlike averaging meters, devices with TRUE RMS show the correct value not only for a sinusoidal waveform, but also for sinusoidal waveforms distorted, e.g. by higher harmonics or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.
NCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in an insulated wire, it can also indicate the phase wire.
LINE - contact detection of alternating voltage, works like a traditional tester. After inserting the measuring probe into the hole in the socket, if a phase is present, the meter will signal its presence.
AUTO - automatic adjustment of the measurement range. When measuring unknown values using a meter with manual range adjustment using a knob, measurements should be taken sequentially from the largest range to the most accurate. Otherwise, we risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to take one measurement and the meter will automatically find the optimal range. The meter starts in AUTO mode by default.
H - DATA HOLD, i.e. keeping the currently measured value on the display.
Additional information:
LCD display, maximum displayed result: 3999
backlighting of the screen and clamp measuring field
sound signal in the continuity test for resistance below 50
clamps open to 26 mm
12 cm long measuring probes
length of the cable with probes: 85 cm
diameter of the cable with insulation: 3.5 mm
insulation of measuring leads: PVC
automatic shutdown of the meter after 20 minutes of inactivity
low battery indicator
power supply: two 1.5 V batteries (AAA)
case included
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.





